2.2.3 Maintain B/L Table
The broadcast/location table must be
maintained to ensure that customer data transmission site records are
kept up to date.
MG6) The SCS shall process each BR (bandwidth/location (B/L) table
update request) command message received from the GCS.
MG6.1) If a BR command message is received and there is already an
entry in the B/L table, the current entry will be replaced.
MG6.2) After the SCS is initialized, table entries are made for all
active communication sites. If the system is restarted, all B/L table
entries must be re-entered.
MG6.3) The SCS has the ability to store 9,999 B/L table entries. Only
one sender (uplink) and receiver (downlink) site pair may be specified
for service during a "Transmit Data" transaction.
MG6.4) The SCS may receive a BR command message after an HR (satellite
health request) command message has been received and processed.
(Describes order during transaction.)
MG6.5) The SCS will only accept A BR command message SCS during an
active "Manage Satellites" transaction. (Describes condition under
which a BR may be received.)
MG7) The SCS shall prepare and send a BA (B/L table updated)
acknowledgment message to the GCS indicating the status of the table
update.
Each acknowledgment message shall contain a status code.
A status code of 1 shall indicate that the B/L table update command was
successful.
A status code of 2 shall indicate that the B/L table is full and that
the system should be restarted.
The corresponding Requirement Behavior Tree is
as below:
|